Παρακολούθηση
David Holder
David Holder
Professor of Biophysics and Clinical Neurophysiology, University College London
Η διεύθυνση ηλεκτρονικού ταχυδρομείου έχει επαληθευτεί στον τομέα ucl.ac.uk - Αρχική σελίδα
Τίτλος
Παρατίθεται από
Παρατίθεται από
Έτος
Electrical impedance tomography: methods, history and applications
A Adler, D Holder
CRC Press, 2021
16772021
Three-dimensional electrical impedance tomography of human brain activity
T Tidswell, A Gibson, RH Bayford, DS Holder
NeuroImage 13 (2), 283-294, 2001
2492001
Electrical impedance tomography: Methods
DS Holder
history and applications 453, 2005
2382005
Electrical impedance tomography of human brain function using reconstruction algorithms based on the finite element method
AP Bagshaw, AD Liston, RH Bayford, A Tizzard, AP Gibson, AT Tidswell, ...
NeuroImage 20 (2), 752-764, 2003
2212003
A review of errors in multi-frequency EIT instrumentation
A McEwan, G Cusick, DS Holder
Physiological measurement 28 (7), S197, 2007
1852007
Imaging fast electrical activity in the brain with electrical impedance tomography
KY Aristovich, BC Packham, H Koo, GS Dos Santos, A McEvoy, ...
NeuroImage 124, 204-213, 2016
1722016
Multi-frequency electrical impedance tomography (EIT) of the adult human head: initial findings in brain tumours, arteriovenous malformations and chronic stroke, development of …
A Romsauerova, A McEwan, L Horesh, R Yerworth, RH Bayford, ...
Physiological measurement 27 (5), S147, 2006
1672006
Electrical impedance tomography method and apparatus
KG Boone, DS Holder
US Patent 5,919,142, 1999
1661999
Clinical and physiological applications of electrical impedance tomography
D Holder
CRC Press, 1993
1631993
Use of anisotropic modelling in electrical impedance tomography; description of method and preliminary assessment of utility in imaging brain function in the adult human head
JFPJ Abascal, SR Arridge, D Atkinson, R Horesh, L Fabrizi, M De Lucia, ...
Neuroimage 43 (2), 258-268, 2008
1472008
Design and calibration of a compact multi-frequency EIT system for acute stroke imaging
A McEwan, A Romsauerova, R Yerworth, L Horesh, R Bayford, D Holder
Physiological measurement 27 (5), S199, 2006
1432006
Current approaches to analogue instrumentation design in electrical impedance tomography
KG Boone, DS Holder
Physiological measurement 17 (4), 229, 1996
1321996
Multi-frequency EIT system with radially symmetric architecture: KHU Mark1
TI Oh, EJ Woo, D Holder
Physiological measurement 28 (7), S183, 2007
1222007
Electrical impedance tomography (EIT) of brain function
DS Holder
Brain topography 5, 87-93, 1992
1201992
Electrical impedance tomography (EIT) of brain function
DS Holder
Brain topography 5, 87-93, 1992
1201992
A versatile and reproducible multi-frequency electrical impedance tomography system
J Avery, T Dowrick, M Faulkner, N Goren, D Holder
Sensors 17 (2), 280, 2017
1112017
Generating accurate finite element meshes for the forward model of the human head in EIT
A Tizzard, L Horesh, RJ Yerworth, DS Holder, RH Bayford
Physiological measurement 26 (2), S251, 2005
1092005
Electrical impedance tomography spectroscopy (EITS) for human head imaging
RJ Yerworth, RH Bayford, B Brown, P Milnes, M Conway, DS Holder
Physiological measurement 24 (2), 477, 2003
1092003
Multifrequency electrical impedance tomography using spectral constraints
E Malone, GS Dos Santos, D Holder, S Arridge
IEEE transactions on medical imaging 33 (2), 340-350, 2013
1022013
Imaging cerebral haemorrhage with magnetic induction tomography: numerical modelling
M Zolgharni, PD Ledger, DW Armitage, DS Holder, H Griffiths
Physiological measurement 30 (6), S187, 2009
992009
Δεν είναι δυνατή η εκτέλεση της ενέργειας από το σύστημα αυτή τη στιγμή. Προσπαθήστε ξανά αργότερα.
Άρθρα 1–20