Design and uncertainty analysis for a PVTt gas flow standard
JD Wright, AN Johnson, MR Moldover
Journal of Research of the National Institute of Standards and Technology …, 2003
852003
NIST calibration services for gas flow meters: piston prover and bell prover gas flow facilities
JD Wright, GE Mattingly
John D. Wright, G E. Mattingly, 1998
511998
Numerical characterization of the discharge coefficient in critical nozzles
AN Johnson, PI Espina, GE Mattingly, JD Wright, CL Merkle
NCSL Workshop & Symposium, 1998
391998
What is the “best” transfer standard for gas flow
JD Wright
Proceedings of FLOMEKO, 12-14, 2003
312003
Self-calibrating open-channel flowmeter
LB Marsh, JD Wright
US Patent 5,684,250, 1997
271997
Microparticle tracking velocimetry as a tool for microfluidic flow measurements
P Salipante, SD Hudson, JW Schmidt, JD Wright
Experiments in Fluids 58, 1-10, 2017
252017
International comparison of a NIST primary standard with an NRLM transfer standard for small mass flow rates of nitrogen gas
JD Wright, GE Mattingly, S Nakao, Y Yokoi, M Takamoto
Metrologia 35 (3), 211, 1998
241998
The long term calibration stability of critical flow nozzles and laminar flowmeters
JD Wright
NCSL Conference Proceedings, Albuquerque, NM, 443-462, 1998
231998
Performance of Coriolis meters in transient gas flows
JG Pope, JD Wright
Flow Measurement and instrumentation 37, 42-53, 2014
222014
Comparison between theoretical CFV flow models and NIST¢s primary flow data in the laminar, turbulent, and transition flow regimes
A Johnson, J Wright
222008
Extended Lee model for the turbine meter & calibrations with surrogate fluids
JG Pope, JD Wright, AN Johnson, MR Moldover
Flow measurement and instrumentation 24, 71-82, 2012
212012
Gas flowmeter calibrations with the 34 L and 677 L PVTt standards
JD Wright, AN Johnson, MR Moldover, GM Kline
NIST Special Publication 250, 63, 2010
212010
Hydrometer calibration by hydrostatic weighing with automated liquid surface positioning
J Aguilera, JD Wright, VE Bean
Measurement Science and Technology 19 (1), 015104, 2007
212007
The effect of vibrational relaxation on the discharge coefficient of critical flow venturis
AN Johnson, JD Wright, S Nakao, CL Merkle, MR Moldover
Flow Measurement and Instrumentation 11 (4), 315-327, 2000
212000
Temperature characterization in the collection tank of the NIST 26 m3 PVTt gas flow standard
AN Johnson, JD Wright, MR Moldover, PI Espina
Metrologia 40 (5), 211, 2003
192003
Calibration of laminar flow meters for process gases
JD Wright, T Cobu, RF Berg, MR Moldover
Flow Measurement and Instrumentation 25, 8-14, 2012
182012
Gas flowmeter calibrations with the 26 m 3 PVTt standard
AN Johnson, JD Wright
NIST Special Publication 1046, 2009
182009
Diverter uncertainty less than 0.01% for water flow calibrations
I Marfenko, TT Yeh, J Wright
6 th International Symposium on Fluid Flow Measurement, 2006
182006
NIST lowers gas flow uncertainties to 0.025% or less
JD Wright, AN Johnson
NCSLI Measure 5 (1), 30-39, 2010
172010
Reproducibility of liquid micro-flow measurements
JD Wright, JW Schmidt
Proceeding of the 18th International Flow Measurement Conference …, 2019
162019