Indoor environmental quality assessment models: A literature review and a proposed weighting and classification scheme D Heinzerling, S Schiavon, T Webster, E Arens Building and environment 70, 210-222, 2013 | 385 | 2013 |
Godly Clergy in Early Stuart England: The Caroline Puritan Movement, c. 1620-1643 T Webster Cambridge University, 1997 | 245 | 1997 |
Outlook for underfloor air distribution F Bauman, T Webster | 198 | 2001 |
Energy savings from extended air temperature setpoints and reductions in room air mixing T Hoyt, KH Lee, H Zhang, E Arens, T Webster | 188 | 2005 |
Detailed loop model (DLM) analysis of liquid solar thermosiphons with heat exchangers A Mertol, W Place, T Webster, R Greif Solar Energy 27 (5), 367-386, 1981 | 127 | 1981 |
Underfloor air distribution: thermal stratification T Webster, F Bauman, J Reese | 117 | 2002 |
Simplified calculation method for design cooling loads in underfloor air distribution (UFAD) systems S Schiavon, KH Lee, F Bauman, T Webster Energy and Buildings 43 (2-3), 517-528, 2011 | 99 | 2011 |
Influence of raised floor on zone design cooling load in commercial buildings S Schiavon, KH Lee, F Bauman, T Webster Energy and buildings 42 (8), 1182-1191, 2010 | 85 | 2010 |
Heat transfer pathways in underfloor air distribution (UFAD) systems F Bauman, H Jin, T Webster | 70 | 2006 |
A post-occupancy monitored evaluation of the dimmable lighting, automated shading, and underfloor air distribution system in The New York Times Building ES Lee, LL Fernandes, B Coffey, A McNeil, R Clear, T Webster, F Bauman, ... | 56 | 2013 |
Thermal decay in underfloor air distribution (UFAD) systems: Fundamentals and influence on system performance KH Lee, S Schiavon, F Bauman, T Webster Applied Energy 91 (1), 197-207, 2012 | 56 | 2012 |
Performance analysis of an integrated UFAD and radiant hydronic slab system P Raftery, KH Lee, T Webster, F Bauman Applied Energy 90 (1), 250-257, 2012 | 54 | 2012 |
Effects of furniture and contents on peak cooling load P Raftery, E Lee, T Webster, T Hoyt, F Bauman Energy and Buildings 85, 445-457, 2014 | 49 | 2014 |
Thermal stratification performance of underfloor air distribution (UFAD) systems T Webster, F Bauman, M Shi, J Reese | 47 | 2002 |
Testing and modeling of underfloor air supply plenums H Jin, F Bauman, T Webster | 45 | 2006 |
How the number and placement of sensors controlling room air distribution systems affect energy use and comfort D Wang, E Arens, T Webster, M Shi | 39 | 2002 |
Cooling airflow design calculations for UFAD F Bauman, T Webster, C Benedek ASHRAE Journal 49, 2007 | 36 | 2007 |
Stratification prediction model for perimeter zone UFAD diffusers based on laboratory testing with solar simulator S Schiavon, T Webster, D Dickerhoff, F Bauman Energy and buildings 82, 786-794, 2014 | 30 | 2014 |
Modeling of underfloor air distribution (UFAD) systems. T Webster, F Bauman, F Buhl, A Daly | 30 | 2008 |
Experimental evaluation of solar thermosyphons with heat exchangers TL Webster, JP Coutier, JW Place, M Tavana Solar Energy 38 (4), 219-231, 1987 | 30 | 1987 |