A novel magnetic resonance elastography transducer concept based on a rotational eccentric mass: preliminary experiences with the gravitational transducer JH Runge, SH Hoelzl, J Sudakova, AS Dokumaci, JL Nelissen, ... Physics in Medicine & Biology 64 (4), 045007, 2019 | 45 | 2019 |
Rheological determinants for simultaneous staging of hepatic fibrosis and inflammation in patients with chronic liver disease R Sinkus, S Lambert, KZ Abd‐Elmoniem, C Morse, T Heller, C Guenthner, ... NMR in Biomedicine 31 (10), e3956, 2018 | 38 | 2018 |
Ristretto MRE: a generalized multi‐shot GRE‐MRE sequence C Guenthner, S Sethi, M Troelstra, AS Dokumaci, R Sinkus, S Kozerke NMR in Biomedicine 32 (5), e4049, 2019 | 34 | 2019 |
Analysis and improvement of motion encoding in magnetic resonance elastography C Guenthner, JH Runge, R Sinkus, S Kozerke NMR in Biomedicine 31 (5), e3908, 2018 | 28 | 2018 |
Encoding and readout strategies in magnetic resonance elastography C Guenthner, S Kozerke NMR in Biomedicine 31 (10), e3919, 2018 | 19 | 2018 |
Shear wave cardiovascular MR elastography using intrinsic cardiac motion for transducer-free non-invasive evaluation of myocardial shear wave velocity MA Troelstra, JH Runge, E Burnhope, A Polcaro, C Guenthner, ... Scientific Reports 11 (1), 1403, 2021 | 12 | 2021 |
Analysis and correction of off‐resonance artifacts in echo‐planar cardiac diffusion tensor imaging RJH van Gorkum, C von Deuster, C Guenthner, CT Stoeck, S Kozerke Magnetic resonance in medicine 84 (5), 2561-2576, 2020 | 12 | 2020 |
A unifying view on extended phase graphs and Bloch simulations for quantitative MRI C Guenthner, T Amthor, M Doneva, S Kozerke Scientific Reports 11 (1), 21289, 2021 | 9 | 2021 |
Fundamentals of turbulent flow spectrum imaging H Dillinger, C McGrath, C Guenthner, S Kozerke Magnetic Resonance in Medicine 87 (3), 1231-1249, 2022 | 8 | 2022 |
Simultaneous multislice acquisition for magnetic resonance elastography C Guenthner, JH Runge, R Sinkus, S Kozerke Proc Intl Soc Mag Reson Med 25, 1132, 2017 | 8 | 2017 |
Characterization and correction of diffusion gradient‐induced eddy currents in second‐order motion‐compensated echo‐planar and spiral cardiac DTI RJH van Gorkum, C Guenthner, A Koethe, CT Stoeck, S Kozerke Magnetic Resonance in Medicine 88 (6), 2378-2394, 2022 | 7 | 2022 |
Direct comparison of gradient Fidelity and acoustic noise of the same MRI system at 3 T and 0. 75 T H Dillinger, S Kozerke, C Guenthner Magnetic Resonance in Medicine 88 (4), 1937-1947, 2022 | 6 | 2022 |
Hadamard encoding for magnetic resonance elastography C Guenthner, JH Runge, R Sinkus, S Kozerke Proceedings of the 25th Annual Meeting ISMRM, 2017 | 6 | 2017 |
Unipolar MR elastography: Theory, numerical analysis and implementation C Guenthner, S Sethi, M Troelstra, RJH Van Gorkum, M Gastl, R Sinkus, ... NMR in Biomedicine 33 (1), e4138, 2020 | 5 | 2020 |
Three-point dixon abdominal water/fat separation using a lower-field 0.75 T MRI C Guenthner, H Dillinger, P Boernert, S Kozerke Intl Soc Mag Reson Med 29, 1283, 2021 | 4 | 2021 |
Ramping down a clinical 3 T scanner: a journey into MRI and MRS at 0.75 T C Guenthner, SM Peereboom, H Dillinger, C McGrath, MM Albannay, ... Magnetic Resonance Materials in Physics, Biology and Medicine 36 (3), 355-373, 2023 | 3 | 2023 |
Abdominal water/fat separated MR fingerprinting on a lower-field 075T MRI C Guenthner, P Koken, P Boernert, S Kozerke Intl Soc Mag Reson Med 29, 499, 2021 | 3 | 2021 |
Direct comparison of gradient modulation transfer functions and acoustic noise spectra of the same MRI at high-(3T) and lower-field (075T) H Dillinger, S Kozerke, C Guenthner Intl Soc Mag Reson Med 29, 2347, 2021 | 3 | 2021 |
Preliminary experience of cardiac proton spectroscopy at 0.75 T SM Peereboom, C Guenthner, MM Albannay, S Kozerke NMR in Biomedicine 36 (7), e4892, 2023 | 2 | 2023 |
Cine flow measurements using phase-contrast bSSFP at 0.75 Tesla E Peper, H Dillinger, C McGrath, C Guenthner, S Kozerke Proc. Int. Soc. Mag. Reson. Med 30, 0092, 2022 | 2 | 2022 |