Παρακολούθηση
Juan Carlos del-Pino-López
Juan Carlos del-Pino-López
Η διεύθυνση ηλεκτρονικού ταχυδρομείου έχει επαληθευτεί στον τομέα us.es - Αρχική σελίδα
Τίτλος
Παρατίθεται από
Παρατίθεται από
Έτος
Influence of different types of magnetic shields on the thermal behavior and ampacity of underground power cables
JC del Pino Lopez, PC Romero
IEEE Transactions on Power Delivery 26 (4), 2659-2667, 2011
662011
A survey on optimization techniques applied to magnetic field mitigation in power systems
JC Bravo-Rodríguez, JC del-Pino-López, P Cruz-Romero
Energies 12 (7), 1332, 2019
642019
Active shielding system for ELF magnetic fields
A Canova, JC del-Pino-López, L Giaccone, M Manca
IEEE Transactions on Magnetics 51 (3), 1-4, 2015
522015
Magnetic field shielding optimization in underground power cable duct banks
JC del-Pino-López, P Cruz-Romero, L Serrano-Iribarnegaray, ...
Electric Power Systems Research 114, 21-27, 2014
512014
A comparative analysis of passive loop-based magnetic field mitigation of overhead lines
PC Romero, JR Santos, JC del Pino López, A de la Villa Jaén, ...
IEEE Transactions on power delivery 22 (3), 1773-1781, 2007
372007
On simplified 3D finite element simulations of three-core armored power cables
JC del-Pino-López, M Hatlo, P Cruz-Romero
Energies 11 (11), 3081, 2018
312018
Design of active loops for magnetic field mitigation in MV/LV substation surroundings
JC del-Pino-López, L Giaccone, A Canova, P Cruz-Romero
Electric Power Systems Research 119, 337-344, 2015
262015
Parametric analysis of magnetic field mitigation shielding for underground power cables
JC del Pino López, PC Romero, P Dula
RE&PQJ 5 (1), 2007
262007
The effectiveness of compensated passive loops for mitigating underground power cable magnetic fields
JC del Pino Lopez, PC Romero
IEEE Transactions on Power Delivery 26 (2), 674-683, 2010
252010
Magnetic field shielding of underground cable duct banks
PL Cruz-Romero, JC Del-Pino-López
Progress In Electromagnetics Research, 138, 1-19., 2013
192013
Ga-based active loop optimization for magnetic field mitigation of MV/LV substations
JC del Pino Lopez, L Giaccone, A Canova, PC Romero
IEEE Latin America Transactions 12 (6), 1055-1061, 2014
152014
Impact of electromagnetic losses in closed two-component magnetic shields on the ampacity of underground power cables
JC del Pino-López, P Cruz-Romero, L Serrano-Iribarnegaray
Progress in electromagnetics research 135, 601-625, 2013
132013
Loss allocation in submarine armored three-core HVAC power cables
JC Del-Pino-Lopez, P Cruz-Romero, LC Sánchez-Díaz
IEEE Transactions on Industry Applications 57 (6), 5706-5715, 2021
122021
Use of 3D-FEM Tools to Improve Loss Allocation in Three-Core Armored Cables
JC del-Pino-López, P Cruz-Romero
Energies 14 (9), 2021
112021
A Thermal Model for Three-Core Armored Submarine Cables Based on Distributed Temperature Sensing
MÁ González-Cagigal, JC del-Pino-López, A Bachiller-Soler, ...
Energies 14 (13), 2021
102021
Evaluation of the power frequency magnetic field generated by three-core armored cables through 3D finite element simulations
JC del-Pino-López, P Cruz-Romero, JC Bravo-Rodríguez
Electric Power Systems Research 213 (108701), 2022
92022
Experimental validation of ultra-shortened 3D finite element electromagnetic modeling of three-core armored cables at power frequency
JC del-Pino-López, P Cruz-Romero
Electric Power Systems Research 203 (107665), 2021
92021
A 3D parametric thermal analysis of submarine three-core power cables
JC del-Pino-López, P Cruz-Romero
18th International Conference on Renewable Energies and Power Quality …, 2020
82020
Thermal effects on the design of passive loops to mitigate the magnetic field generated by underground power cables
JC del Pino Lopez, PC Romero
IEEE transactions on power delivery 26 (3), 1718-1726, 2011
82011
Metodologías activas de enseñanza en la docencia de instalaciones eléctricas
JC del Pino López, MB Payán
Revista de Enseñanza Universitaria, 28-40, 2010
72010
Δεν είναι δυνατή η εκτέλεση της ενέργειας από το σύστημα αυτή τη στιγμή. Προσπαθήστε ξανά αργότερα.
Άρθρα 1–20