Eduardo Lage
Title
Cited by
Cited by
Year
NEMA NU 4-2008 comparison of preclinical PET imaging systems
AL Goertzen, Q Bao, M Bergeron, E Blankemeyer, S Blinder, M Cañadas, ...
Journal of Nuclear Medicine 53 (8), 1300-1309, 2012
2042012
Assessment of a new high-performance small-animal X-ray tomograph
JJ Vaquero, S Redondo, E Lage, M Abella, A Sisniega, G Tapias, ...
IEEE transactions on nuclear science 55 (3), 898-905, 2008
742008
rPET detectors design and data processing
JJ Vaquero, E Lage, L Ricon, M Abella, E Vicente, M Desco
IEEE Nuclear Science Symposium Conference Record, 2005 5, 2885-2889, 2005
502005
Design and performance evaluation of a coplanar multimodality scanner for rodent imaging
E Lage, JJ Vaquero, A Sisniega, S Espana, G Tapias, M Abella, ...
Physics in Medicine & Biology 54 (18), 5427, 2009
472009
NEMA NU 4-2008 performance measurements of two commercial small-animal PET scanners: ClearPET and rPET-1
M Cañadas, M Embid, E Lage, M Desco, JJ Vaquero, JM Pérez
IEEE Transactions on Nuclear Science 58 (1), 58-65, 2010
342010
From Unseen to Seen: Tackling the Global Burden of Uncorrected Refractive Errors
NJ Durr, D Shivang R., L Eduardo, S Marcos, D Thorn, Frank, Lim
Annual Reviews of Biomedical Engineering 16, 131-153, 2014
262014
Multimodality workstation for small animal image visualization and analysis
J Pascau, JJ Vaquero, M Abella, R Cacho, E Lage, M Desco
Molecular Imaging and Biology 8 (2), 97-98, 2006
262006
Simulation of Triple coincidences in PET
J Cal-Gonzalez, E Lage, E Herranz, E Vicente, JM Udias, SC Moore, ...
Physics in Medicine and Biology 60 (1), 117, 2014
222014
Simulation of Triple Coincidences in PET
J Cal-González, E Herranz, E Vicente, JM Udías, SR Dave, V Parot, ...
IEEE Nuclear Science Symposium and Medical Imaging Conference, 0
22*
Recovery and Normalization of triple coincidences in PET
E Lage, V Parot, SC Moore, A Sitek, JM Udias, SR Dave, MA Park, ...
Medical Physics 42 (3), 1398-1410, 2015
212015
Design and development of a high performance micro-CT system for small-animal imaging
E Lage Negro, JJ Vaquero López, S Redondo, M Abella García, G Tapias, ...
IEEE, 2006
16*2006
Sinogram bow‐tie filtering in FBP PET reconstruction
M Abella, JJ Vaquero, ML Soto‐Montenegro, E Lage, M Desco
Medical physics 36 (5), 1663-1671, 2009
152009
Design and Clinical Evaluation of a Handheld Wavefront Autorefractor
NJ Durr, SR Dave, FA Vera-Diaz, D Lim, C Dorronsoro, S Marcos, F Thorn, ...
Optometry and Vision Science 92 (12), 1140-1147, 2015
132015
Co-planar PET/CT for small animal imaging
JJ Vaquero, E Lage, S Redondo, M Abella, J Pascau, J Sanchez, ...
IEEE Nuclear Science Symposium Conference Record, 2005 3, 4 pp.-1751, 2005
132005
Automatic Monte-Carlo based scatter correction for x-ray cone-beam CT using general purpose graphic processing units (gp-gpu): a feasibility study
A Sisniega, M Abella, E Lage, M Desco, JJ Vaquero
2011 IEEE Nuclear Science Symposium Conference Record, 3705-3709, 2011
112011
A SPECT scanner for rodent imaging based on small-area gamma cameras
E Lage, JL Villena, G Tapias, NP Martínez, ML Soto-Montenegro, ...
IEEE Transactions on Nuclear Science 57 (5), 2524-2531, 2010
92010
Performance evaluation of a new gamma imager for small animal SPECT applications
E Lage, JJ Vaquero, J Villena, A De Carlos, G Tapias, A Sisniega, ...
2007 IEEE Nuclear Science Symposium Conference Record 5, 3355-3360, 2007
92007
Assessment of a new CT system for small animals
S Redondo, JJ Vaquero, E Lage, M Abella, G Tapias, A Udias, M Desco
2006 IEEE Nuclear Science Symposium Conference Record 6, 3553-3556, 2006
82006
Design of DOI PET detector modules using phoswich and SiPMs: First results
JJ Vaquero, JJ Sñnchez, E Lage, JM Udías, P Guerra, M Desco
2011 IEEE Nuclear Science Symposium Conference Record, 3311-3313, 2011
72011
VrPET/CT: Development of a rotating multimodality scanner for small-animal imaging
E Lage, JJ Vaquero, A Sisniega, S España, G Tapias, Á Udías, V García, ...
2008 IEEE Nuclear Science Symposium Conference Record, 4671-4674, 2008
72008
The system can't perform the operation now. Try again later.
Articles 1–20