Daniel Sánchez
Title
Cited by
Cited by
Year
Energetic evaluation of an internal heat exchanger in a CO2 transcritical refrigeration plant using experimental data
E Torrella, D Sánchez, R Llopis, R Cabello
International Journal of Refrigeration 34 (1), 40-49, 2011
234*2011
Energy performance evaluation of R1234yf, R1234ze (E), R600a, R290 and R152a as low-GWP R134a alternatives
D Sánchez, R Cabello, R Llopis, I Arauzo, J Catalán-Gil, E Torrella
International Journal of Refrigeration 74, 269-282, 2017
1562017
Experimental evaluation of the energy efficiency of a CO2 refrigerating plant working in transcritical conditions
R Cabello, D Sánchez, R Llopis, E Torrella
Applied thermal engineering 28 (13), 1596-1604, 2008
1052008
A simplified model for shell-and-tubes heat exchangers: Practical application
F Vera-García, JR García-Cascales, J Gonzálvez-Maciá, R Cabello, ...
Applied thermal engineering 30 (10), 1231-1241, 2010
1022010
Experimental evaluation of a CO2 transcritical refrigeration plant with dedicated mechanical subcooling
R Llopis, L Nebot-Andrés, R Cabello, D Sánchez, J Catalán-Gil
International journal of refrigeration 69, 361-368, 2016
1012016
Subcooling methods for CO2 refrigeration cycles: A review
R Llopis, L Nebot-Andrés, D Sánchez, J Catalán-Gil, R Cabello
International Journal of Refrigeration 93, 85-107, 2018
962018
Energy and environmental comparison of two-stage solutions for commercial refrigeration at low temperature: Fluids and systems
R Llopis, D Sánchez, C Sanz-Kock, R Cabello, E Torrella
Applied Energy 138, 133-142, 2015
892015
Experimental evaluation of a R134a/CO2 cascade refrigeration plant
C Sanz-Kock, R Llopis, D Sánchez, R Cabello, E Torrella
Applied Thermal Engineering 73 (1), 41-50, 2014
742014
Influence of the superheat associated to a semihermetic compressor of a transcritical CO2 refrigeration plant
D Sánchez, E Torrella, R Cabello, R Llopis
Applied Thermal Engineering 30 (4), 302-309, 2010
672010
Performance evaluation of R404A and R507A refrigerant mixtures in an experimental double-stage vapour compression plant
R Llopis, E Torrella, R Cabello, D Sánchez
Applied Energy 87 (5), 1546-1553, 2010
572010
Energy evaluation of R152a as drop in replacement for R134a in cascade refrigeration plants
R Cabello, D Sánchez, R Llopis, J Catalán, L Nebot-Andrés, E Torrella
Applied Thermal Engineering 110, 972-984, 2017
522017
Experimental comparison between R152a and R134a working in a refrigeration facility equipped with a hermetic compressor
R Cabello, D Sánchez, R Llopis, I Arauzo, E Torrella
international journal of refrigeration 60, 92-105, 2015
502015
New positions for an internal heat exchanger in a CO2 supercritical refrigeration plant. Experimental analysis and energetic evaluation
D Sánchez, J Patiño, R Llopis, R Cabello, E Torrella, FV Fuentes
Applied Thermal Engineering 63 (1), 129-139, 2014
472014
A new approach to optimize the energy efficiency of CO2 transcritical refrigeration plants
I Peñarrocha, R Llopis, L Tárrega, D Sánchez, R Cabello
Applied Thermal Engineering 67 (1-2), 137-146, 2014
452014
Experimental evaluation of an internal heat exchanger in a CO2 subcritical refrigeration cycle with gas-cooler
R Llopis, C Sanz-Kock, R Cabello, D Sánchez, E Torrella
Applied Thermal Engineering 80, 31-41, 2015
402015
HCFC-22 replacement with drop-in and retrofit HFC refrigerants in a two-stage refrigeration plant for low temperature
R Llopis, E Torrella, R Cabello, D Sánchez
International journal of refrigeration 35 (4), 810-816, 2012
392012
A general methodology for energy comparison of intermediate configurations in two-stage vapour compression refrigeration systems
E Torrella, JA Larumbe, R Cabello, R Llopis, D Sanchez
Energy 36 (7), 4119-4124, 2011
392011
Effects caused by the internal heat exchanger at the low temperature cycle in a cascade refrigeration plant
R Llopis, C Sanz-Kock, R Cabello, D Sánchez, L Nebot-Andrés, ...
Applied Thermal Engineering 103, 1077-1086, 2016
382016
Conversion of a direct to an indirect commercial (HFC134a/CO2) cascade refrigeration system: Energy impact analysis
D Sánchez, R Llopis, R Cabello, J Catalán-Gil, L Nebot-Andrés
International Journal of Refrigeration 73, 183-199, 2017
372017
Experimental analysis of energy performance of modified single-stage CO2 transcritical vapour compression cycles based on vapour injection in the suction line
R Cabello, D Sánchez, J Patiño, R Llopis, E Torrella
Applied Thermal Engineering 47, 86-94, 2012
372012
The system can't perform the operation now. Try again later.