Prevalence of corneal astigmatism before cataract surgery T Ferrer-Blasco, R Montés-Micó, SC Peixoto-de-Matos, ... Journal of Cataract & Refractive Surgery 35 (1), 70-75, 2009 | 588 | 2009 |
Analysis of the possible benefits of aspheric intraocular lenses: review of the literature R Montés-Micó, T Ferrer-Blasco, A Cerviño Journal of Cataract & Refractive Surgery 35 (1), 172-181, 2009 | 196 | 2009 |
Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry JM González-Méijome, A Cerviño, E Yebra-Pimentel, MA Parafita Journal of Cataract & Refractive Surgery 29 (1), 125-132, 2003 | 194 | 2003 |
Apodized diffractive versus refractive multifocal intraocular lenses: optical and visual evaluation B Żelichowska, M Rękas, A Stankiewicz, A Cerviño, R Montés-Micó Journal of Cataract & Refractive Surgery 34 (12), 2036-2042, 2008 | 130 | 2008 |
The tear film and the optical quality of the eye R Montés-Micó, A Cervino, T Ferrer-Blasco, S García-Lázaro, ... The ocular surface 8 (4), 185-192, 2010 | 128 | 2010 |
Retinal straylight and complaint scores 18 months after implantation of the AcrySof monofocal and ReSTOR diffractive intraocular lenses T Hofmann, B Zuberbuhler, A Cervino, R Montés-Micó, E Haefliger Journal of Refractive Surgery 25 (6), 485-492, 2009 | 95 | 2009 |
Effect of contact lens surface properties on comfort, tear stability and ocular physiology M Vidal-Rohr, JS Wolffsohn, LN Davies, A Cerviño Contact Lens and Anterior Eye 41 (1), 117-121, 2018 | 87 | 2018 |
Performance of the compensation comparison method for retinal straylight measurement: effect of patient’s age on repeatability A Cervino, R Montes-Mico, SL Hosking British Journal of Ophthalmology 92 (6), 788-791, 2008 | 85 | 2008 |
Retinal straylight in patients with monofocal and multifocal intraocular lenses A Cerviño, SL Hosking, R Montés-Micó, JL Alió Journal of Cataract & Refractive Surgery 34 (3), 441-446, 2008 | 79 | 2008 |
Clinical ocular wavefront analyzers A Cerviño, SL Hosking, R Montes-Mico, K Bates Journal of refractive surgery 23 (6), 603-616, 2007 | 76 | 2007 |
Visual performance with simultaneous vision multifocal contact lenses A Llorente‐Guillemot, S García‐Lazaro, T Ferrer‐Blasco, ... Clinical and Experimental Optometry 95 (1), 54-59, 2012 | 72 | 2012 |
Use of digital displays and ocular surface alterations: a review C Talens-Estarelles, JV García-Marqués, A Cervino, S García-Lázaro The Ocular Surface 19, 252-265, 2021 | 71 | 2021 |
Accuracy and precision of EyeSys and Orbscan systems on calibrated spherical test surfaces JG Pérez, A Cervino, MJ Giraldez, M Parafita, E Yebra-Pimentel Eye & Contact Lens 30 (2), 74-78, 2004 | 70 | 2004 |
Optical quality of the diabetic eye: a review AM Calvo-Maroto, RJ Perez-Cambrodí, C Albarán-Diego, A Pons, ... Eye 28 (11), 1271-1280, 2014 | 68 | 2014 |
Long-term comparison of corneal aberration changes after laser in situ keratomileusis: mechanical microkeratome versus femtosecond laser flap creation G Muñoz, C Albarrán-Diego, T Ferrer-Blasco, S García-Lázaro, ... Journal of Cataract & Refractive Surgery 36 (11), 1934-1944, 2010 | 66 | 2010 |
Changes in corneal structure with continuous wear of high-Dk soft contact lenses: a pilot study JM González-Méijome, J González-Pérez, A Cerviño, E Yebra-Pimentel, ... Optometry and vision science 80 (6), 440-446, 2003 | 66 | 2003 |
Optical quality after instillation of eyedrops in dry-eye syndrome R Montés-Micó, A Cerviño, T Ferrer-Blasco, S García-Lázaro, ... Journal of Cataract & Refractive Surgery 36 (6), 935-940, 2010 | 64 | 2010 |
A comparison of two pachymetric systems: slit-scanning and ultrasonic MJG Fernandez, AD Rey, A Cerviño, E Yebra-Pimentel Eye & Contact Lens 28 (4), 221-223, 2002 | 62 | 2002 |
Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens R Montés-Micó, T Ferrer-Blasco, WN Charman, A Cerviño, JF Alfonso, ... Journal of Cataract & Refractive Surgery 34 (5), 763-768, 2008 | 59 | 2008 |
Quantitative corneal anatomy: evaluation of the effect of diabetes duration on the endothelial cell density and corneal thickness AM Calvo‐Maroto, A Cervino, RJ Perez‐Cambrodí, S García‐Lázaro, ... Ophthalmic and Physiological Optics 35 (3), 293-298, 2015 | 58 | 2015 |