Follow
Thomas Heldt
Title
Cited by
Cited by
Year
Multiparameter Intelligent Monitoring in Intensive Care II: a public-access intensive care unit database
M Saeed, M Villarroel, AT Reisner, G Clifford, LW Lehman, G Moody, ...
Critical care medicine 39 (5), 952-960, 2011
13052011
An open-source algorithm to detect onset of arterial blood pressure pulses
W Zong, T Heldt, GB Moody, RG Mark
Computers in Cardiology, 2003, 259-262, 2003
4132003
Computational modeling of cardiovascular response to orthostatic stress
T Heldt, EB Shim, RD Kamm, RG Mark
Journal of applied physiology 92 (3), 1239-1254, 2002
3892002
Model-based noninvasive estimation of intracranial pressure from cerebral blood flow velocity and arterial pressure
FM Kashif, GC Verghese, V Novak, M Czosnyka, T Heldt
Science translational medicine 4 (129), 129ra44-129ra44, 2012
1542012
Presenting symptoms independently predict mortality in septic shock: importance of a previously unmeasured confounder
MR Filbin, J Lynch, TD Gillingham, JE Thorsen, CL Pasakarnis, S Nepal, ...
Critical care medicine 46 (10), 1592-1599, 2018
1302018
CVSim: an open-source cardiovascular simulator for teaching and research
T Heldt, R Mukkamala, GB Moody, RG Mark
The open pacing, electrophysiology & therapy journal 3, 45, 2010
862010
The cardiac output from blood pressure algorithms trial
JX Sun, AT Reisner, M Saeed, T Heldt, RG Mark
Critical care medicine 37 (1), 72-80, 2009
802009
Computational models of cardiovascular response to orthostatic stress
T Heldt
Massachusetts Institute of Technology, 2004
762004
Circulatory response to passive and active changes in posture
T Heldt, MB Oefinger, M Hoshiyama, RG Mark
Computers in Cardiology, 2003, 263-266, 2003
722003
Systems and methods for model-based estimation of cardiac output and total peripheral resistance
TA Parlikar, GV Ranade, T Heldt, GC Verghese
US Patent 8,282,564, 2012
662012
A multidimensional approach to pain assessment in critically ill infants during a painful procedure
M Ranger, CC Johnston, JE Rennick, C Limperopoulos, T Heldt, ...
The Clinical journal of pain 29 (7), 613-620, 2013
622013
The ear as a location for wearable vital signs monitoring
D Da He, ES Winokur, T Heldt, CG Sodini
2010 Annual International Conference of the IEEE Engineering in Medicine and …, 2010
602010
Integrating data, models, and reasoning in critical care
T Heldt, B Long, GC Verghese, P Szolovits, RG Mark
2006 International Conference of the IEEE Engineering in Medicine and …, 2006
582006
Automated quantitative analysis of capnogram shape for COPD–normal and COPD–CHF classification
RJ Mieloszyk, GC Verghese, K Deitch, B Cooney, A Khalid, ...
IEEE Transactions on Biomedical Engineering 61 (12), 2882-2890, 2014
572014
Intracranial pressure and intracranial elastance monitoring in neurocritical care
T Heldt, T Zoerle, D Teichmann, N Stocchetti
Annual review of biomedical engineering 21, 523-549, 2019
562019
A QT interval detection algorithm based on ECG curve length transform
W Zong, M Saeed, T Heldt
2006 Computers in Cardiology, 377-380, 2006
492006
Numerical analysis of blood flow through a stenosed artery using a coupled multiscale simulation method
EB Shim, RD Kamm, T Heldt, RG Mark
Computers in Cardiology 2000. Vol. 27 (Cat. 00CH37163), 219-222, 2000
412000
Model-based estimation of cardiac output and total peripheral resistance
TA Parlikar, T Heldt, GV Ranade, GC Verghese
2007 Computers in Cardiology, 379-382, 2007
402007
Fully automated, real-time, calibration-free, continuous noninvasive estimation of intracranial pressure in children
A Fanelli, FW Vonberg, KL LaRovere, BK Walsh, ER Smith, S Robinson, ...
Journal of Neurosurgery: Pediatrics 24 (5), 509-519, 2019
372019
Systems, devices and methods for noninvasive or minimally-invasive estimation of intracranial pressure and cerebrovascular autoregulation
FM Kashif, T Heldt, GC Verghese
US Patent 8,366,627, 2013
372013
The system can't perform the operation now. Try again later.
Articles 1–20