Follow
Bayford
Bayford
Verified email at mdx.ac.uk
Title
Cited by
Cited by
Year
GREIT: a unified approach to 2D linear EIT reconstruction of lung images
A Adler, JH Arnold, R Bayford, A Borsic, B Brown, P Dixon, TJC Faes, ...
Physiological measurement 30 (6), S35, 2009
7522009
Bioimpedance tomography (electrical impedance tomography)
RH Bayford
Annu. Rev. Biomed. Eng. 8 (1), 63-91, 2006
5452006
Three-dimensional electrical impedance tomography of human brain activity
T Tidswell, A Gibson, RH Bayford, DS Holder
NeuroImage 13 (2), 283-294, 2001
2572001
Electrical impedance tomography of human brain function using reconstruction algorithms based on the finite element method
AP Bagshaw, AD Liston, RH Bayford, A Tizzard, AP Gibson, AT Tidswell, ...
NeuroImage 20 (2), 752-764, 2003
2242003
Whither lung EIT: where are we, where do we want to go and what do we need to get there?
A Adler, MB Amato, JH Arnold, R Bayford, M Bodenstein, SH Böhm, ...
Physiological measurement 33 (5), 679, 2012
2132012
Multi-frequency electrical impedance tomography (EIT) of the adult human head: initial findings in brain tumours, arteriovenous malformations and chronic stroke, development of …
A Romsauerova, A McEwan, L Horesh, R Yerworth, RH Bayford, ...
Physiological measurement 27 (5), S147, 2006
1732006
Use of anisotropic modelling in electrical impedance tomography; description of method and preliminary assessment of utility in imaging brain function in the adult human head
JFPJ Abascal, SR Arridge, D Atkinson, R Horesh, L Fabrizi, M De Lucia, ...
Neuroimage 43 (2), 258-268, 2008
1502008
Design and calibration of a compact multi-frequency EIT system for acute stroke imaging
A McEwan, A Romsauerova, R Yerworth, L Horesh, R Bayford, D Holder
Physiological measurement 27 (5), S199, 2006
1462006
Electrical impedance tomography spectroscopy (EITS) for human head imaging
RJ Yerworth, RH Bayford, B Brown, P Milnes, M Conway, DS Holder
Physiological measurement 24 (2), 477, 2003
1142003
Generating accurate finite element meshes for the forward model of the human head in EIT
A Tizzard, L Horesh, RJ Yerworth, DS Holder, RH Bayford
Physiological measurement 26 (2), S251, 2005
1122005
Detection of the tau protein in human serum by a sensitive four-electrode electrochemical biosensor
SX Wang, D Acha, AJ Shah, F Hills, I Roitt, A Demosthenous, RH Bayford
Biosensors and bioelectronics 92, 482-488, 2017
1002017
A human–machine interface using electrical impedance tomography for hand prosthesis control
Y Wu, D Jiang, X Liu, R Bayford, A Demosthenous
IEEE transactions on biomedical circuits and systems 12 (6), 1322-1333, 2018
972018
Factors limiting the application of electrical impedance tomography for identification of regional conductivity changes using scalp electrodes during epileptic seizures in humans
L Fabrizi, M Sparkes, L Horesh, JFPJ Abascal, A McEwan, RH Bayford, ...
Physiological measurement 27 (5), S163, 2006
952006
Bioimpedance imaging: an overview of potential clinical applications
R Bayford, A Tizzard
Analyst 137 (20), 4635-4643, 2012
932012
Emerging applications of nanotechnology for diagnosis and therapy of disease: a review
R Bayford, T Rademacher, I Roitt, SX Wang
Physiological measurement 38 (8), R183, 2017
922017
Design and performance of the UCLH Mark 1b 64 channel electrical impedance tomography (EIT) system, optimized for imaging brain function
RJ Yerworth, RH Bayford, G Cusick, M Conway, DS Holder
Physiological measurement 23 (1), 149, 2002
882002
A high frame rate wearable EIT system using active electrode ASICs for lung respiration and heart rate monitoring
Y Wu, D Jiang, A Bardill, S De Gelidi, R Bayford, A Demosthenous
IEEE Transactions on Circuits and Systems I: Regular Papers 65 (11), 3810-3820, 2018
852018
Electrical impedance tomography of human brain activity with a two-dimensional ring of scalp electrodes
AT Tidswell, A Gibson, RH Bayford, DS Holder
Physiological measurement 22 (1), 167, 2001
852001
Validation of a 3D reconstruction algorithm for EIT of human brain function in a realistic head-shaped tank
AT Tidswell, A Gibson, RH Bayford, DS Holder
Physiological measurement 22 (1), 177, 2001
792001
The influence of ligand organization on the rate of uptake of gold nanoparticles by colorectal cancer cells
T Lund, MF Callaghan, P Williams, M Turmaine, C Bachmann, ...
Biomaterials 32 (36), 9776-9784, 2011
782011
The system can't perform the operation now. Try again later.
Articles 1–20